
Products

The most comprehensive panel of fully automated Hemostasis assays, designed for disease-state management. From routine to specialty testing, HemosIL reagents deliver fast, accurate results. Robust offering of liquid, ready-to-use assays enhance efficiency of lab operations and ultimately, patient care.
Standardized and automated, delivering fast, reliable results.
Broadest liquid, ready-to-use portfolio for quality and efficiency
We offer more liquid, ready-to-use Hemostasis assays than any other manufacturer. A typical lab can meet 91% of its Hemostasis testing needs with HemosIL liquid, ready-to-use assays, including PT, APTT, D-Dimer and Antithrombin. Eliminating reconstitution time, acclimation time and repetitive manual pipetting, leads to greater efficiency and better patient care. And, HemosIL assays enhance management of disease-states, from Heparin-Induced Thrombocytopenia and Antiphospholipid Syndrome, to von Willebrand Disease, Thrombophila, and more.
- General Screening and Anticoagulant Monitoring
- PT
- RecombiPlasTin® 2G
- ReadiPlasTin®
- APTT
- Synth ASil ®
- SynthAFax ®
- APTT-SP
- Fibrinogen Clauss
- Fib-C
- Q.F.A. Thrombin
- Other
- Thrombin Time
- INR Validate
- ISI Calibrate
- PT
- D-Dimer
- D-Dimer HS 500
- D-Dimer 500*
- D-Dimer HS
- D-Dimer
- D-Dimer HS 2000*
- AcuStar D-Dimer
- UF/LMW Heparin
- Liquid Anti-Xa (1 stage)
- Heparin (2 stage)
- DOACs
- Dabigatran (DTI)*
- Rivaroxaban (Liquid Anti-Xa)*
- Apixaban (Liquid Anti-Xa)
- Antiphospholipid Syndrome
- Silica Clotting Time
- dRVVT Screen
- dRVVT Confirm
- AcuStar aCL IgG
- AcuStar aCL IgM
- AcuStar aβ2GPI IgG
- AcuStar aβ2GPI IgM
- AcuStar aβ2GPI Domain 1*
- Heparin-Induced Thrombocytopenia
- HIT-Ab(PF4-H)
- AcuStar HIT-IgG(PF4-H)
- von Willebrand Disease
- VWF Antigen
- VWF Activity
- VWF Ristocetin Cofactor
- Activity*
- AcuStar VWF Antigen*
- AcuStar Ristocetin
- Cofactor Activity*
- AcuStar VWF CB*
- Fibrin Formation and Degradation
- FDP*
- Plasminogen
- Plasmin Inhibitor
- Thrombophilia
- Liquid Antithrombin
- Protein C (Chromogenic)
- Protein C (Clotting)
- Free Protein S (Antigenic)
- Protein S Activity (Clotting)
- FV Leiden (APC-R V)
- Homocysteine
- Xpert HemosIl® FII & FV
- Coagulation Factors
- Intrinsic Factors
- Extrinsic Factors
- FXIII Antigen
- Liquid, ready-to-use format
- * Not 510(k) cleared, not available in all countries
General Screening and Anticoagulant Testing
Broad assay menu for tailored testing
HemosIL PT reagents offer consistent performance sensitivity to enable optimal monitoring of oral anticoagulant therapy and evaluation of the extrinsic coagulation pathway. Highly stable and always consistent for moderate to high sensitivity. HemosIL APTT reagents enable optimal monitoring of therapeutic coagulation inhibitors and screening of the intrinsic coagulation pathyway with excellent sensitivity and lot-to-lot consistency. The General Screening Panel also includes Fibrinogen assays to assess bleeding risk in patients with unexplained prolonged PT or APTT results.
Consistency, test after test, for optimal efficiency.
HemosIL APTT-SP
HemosIL Fibrinogen-C
HemosIL Fibrinogen-C XL
HemosIL Liquid Anti-Xa
HemosIL Liquid Heparin Calibrators
HemosIL LMW Heparin Controls
HemosIL Q.F.A. Thrombin 2ml
HemosIL Q.F.A. Thrombin 5ml
HemosIL ReadiPlasTin 20mL
HemosIL RecombiPlasTin 2G 20mL
HemosIL RecombiPlasTin 2G 8mL
HemosIL SynthAFax
HemosIL SynthASil
HemosIL Thrombin Time
HemosIL UF Heparin Controls
Direct Oral Anticoagulant Measurement
Superior performance for accurate DOAC testing
Direct Oral Anticoagulants (DOACs), such as dabigatran and rivaroxaban, do not require routine monitoring. However, there are instances when determining levels of these drugs may be warranted. The HemosIL DOAC Assay Panel provides superior analytical performance in a standardized and validated automated solution.
HemosIL Apixaban Calibrators
HemosIL Apixaban Controls
HemosIL Dabigatran Calibrators
HemosIL Dabigatran Controls
HemosIL Direct Thrombin Inhibitor Assay
HemosIL Rivaroxaban Calibrators
HemosIL Rivaroxaban Controls
Fibrin formation and degradation
Fully automated for the timely exclusion of VTE 100% NPV.
HemosIL D-Dimer assays are clinically validated with cut-off values for the exclusion of venous thromboembolism (VTE), including both pulmonary embolism (PE) and deep vein thrombosis (DVT), in conjunction with a pretest probability assessment. This approach can reduce the need for costly and invasive imaging tests, typical in the diagnosis of VTE. HemosIL D-Dimer assays offer reliable results in minutes, are highly specific, and fully automated on ACL testing systems, optimizing laboratory workflow.
AcuStar D-Dimer **
AcuStar D-Dimer Controls **
HemosIL D-Dimer HS 500
HemosIL D-Dimer HS 500 Controls (Liquid)
HemosIL Factor XIII Antigen
HemosIL FDP
HemosIL FDP Calibrator
HemosIL FDP Controls
HemosIL Plasmin Inhibitor
HemosIL Plasminogen
** Chemiluminescent technology assay. For Use on ACL AcuStar Hemostasis Testing System.
Antiphospholipid Syndrome
HemosIL Lupus Anticoagulant (LA) Assay Panel
Guidelines for LA testing call for two types of tests, Dilute Russell Viper Venom Test (dRVVT) and an
APTT-based assay with a silica activator. Only Werfen offers both tests in a single, fully automated panel.
HemosIL AcuStar Antiphospholipid Assay Panel
Complete your automated APS testing with HemosIL AcuStar specialty reagents on the ACL AcuStar testing system.
AcuStar Anti-Cardiolipin Controls IgG **
AcuStar Anti-Cardiolipin Controls IgM **
AcuStar Anti-Cardiolipin IgG **
AcuStar Anti-β2 Glycoprotein-I IgG **
AcuStar Anti-β2 Glycoprotein-I IgG Controls**
AcuStar Anti-β2 Glycoprotein-I IgM **
AcuStar Anti-β2 Glycoprotein-I IgM Controls **
AcuStar Anticardiolipin IgM **
AcuStar Multi-Ab Controls [**]
HemosIL dRVVT Confirm
HemosIL dRVVT Screen
HemosIL LA Negative Control
HemosIL LA Positive Control
HemosIL Silica Clotting Time
** Chemiluminescent technology assay. For Use on ACL AcuStar Hemostasis Testing System.
Heparin-Induced Thrombocytopenia
HIT Testing in Minutes
The first on-demand fully automated assays for HIT antibody detection on Hemostasis systems.
Simple, fully automated and ready to use, results are available in minutes, and on-demand 24/7.
Detects anti-Platelet Factor 4-heparin (anti-PF4-H) antibodies for analytical excellence in agreement with ELISA methods. Reduces staff time and costs and enhances patient management decisions. Assays available for ACL TOP systems, as well as ACL AcuStar systems.*
The on-demand solution that saves more than time.
AcuStar HIT-Controls [**]
AcuStar HIT-IgG(PF4-H) [**]
HemosIL HIT-Ab(PF4-H)
HemosIL HIT-Ab(PF4-H) Controls
** Chemiluminescent technology assay. For Use on ACL AcuStar Hemostasis Testing System.
von Willebrand Disease
Simply complete
All von Willebrand Factor (VWF) assays are fully automated with rapid time to result (<12 minutes), excellent onboard stability and correlation with existing methods. Activity, antigen and factor deficiency detection for complete VWD investigation. Assay panels available for ACL TOP systems, as well as ACL AcuStar systems.
AcuStar von Willebrand Factor: Ag [**]
AcuStar von Willebrand Factor: CB [**]
AcuStar von Willebrand Factor: Controls [**]
AcuStar von Willebrand Factor: RCo [**]
HemosIL von Willebrand Factor Activity
HemosIL von Willebrand Factor Antigen
HemosIL von Willebrand Factor Ristocetin Cofactor
** Chemiluminescent technology assay. For Use on ACL AcuStar Hemostasis Testing System.
Fibrinolysis
Comprehensive and simple detection of fibrinolytic disorders
Fully automated and easy to use, the HemosIL Fibrinolysis Assay Panel includes liquid, ready-to-use FDP assay* with innovative immunoassaythat mitigates fibrinogen interference, Plasminogen assay, and Plasminogen Inhibitor assay, capable of detecting homozygous plasmin-inhibitor-deficiency.
Thrombophilia
Specialty testing as simple as routine
Antithrombin (AT)
HemosIL Liquid AT is the only ready-to-use AT assay and features enhanced reagent stability and improved onboard stability. Convenient to use and available in three kit sizes to address all test volume requirements.
Homocysteine
The first fully automated, immunoturbidimetric assay for Hemostasis testing. Featuring linearity up to 60 µmol/L, the assay is designed for use with citrated plasma and can be incorporated into a thrombophilia panel.
Protein C Pathway
Includes Protein C and S, as well as a chromogenic Protein C assay (activity), all with excellent stability, linearity and specificity. Free Protein S reagent features the affinity of a polyclonal antibody and the specificity of a monoclonal antibody for enhanced analytical performance.
Activated Protein C (APC) Resistance
Includes a patented test for APC resistance caused by the Factor V:Q506 mutation that allows highly specific FV Leiden detection with >99% sensitivity. Test results not affected by oral anticoagulant or heparin present in plasma samples (up to 1 U/mL).
COATEST APC Resistance
COATEST APC Resistance Control Plasma Level 1
COATEST APC Resistance Control Plasma Level 2
HemosIL Factor V Leiden (APC™ Resistance V)
HemosIL FII & FV DNA Control
HemosIL Free Protein S
HemosIL Homocysteine
HemosIL Homocysteine Controls
HemosIL Liquid Antithrombin 2ml
HemosIL Liquid Antithrombin 4,5ml
HemosIL ProClot
HemosIL ProClot Diluent
HemosIL Protein C
HemosIL Protein S Activity
Thrombotic Thrombocytopenic Purpura
On-demand TTP testing for fast, informed clinical decisions
HemosIL AcuStar ADAMTS13 Activity assay is the only automated, on-demand test to aid in the diagnosis and monitoring of TTP, with the superior analytical sensitivity of chemiluminescence technology.
Rapid, with first results in approximately 30 minutes
HemosIL AcuStar VWF Controls**
HemosIL ADAMTS13 Activity Assay
Coagulation Factors
Comprehensive, easy and efficient
Spanning the entire coagulation cascade, these deficient plasmas are used in combination with a selected PT and APTT reagent for the determination of specific Factor activity in citrated plasma on ACL TOP systems. Includes a complete range of immunodepleted factor deficiency plasmas with < 1% residual activity and 24-hour onboard stability, reducing reagent waste. Liquid, ready-to-use FXIII Antigen is fully automated, adding convenience vs manual, less specific clot-solubility method.
COAMATIC FVIII
COASET FVII
COATEST SP FVIII
HemosIL FII Deficient Plasma
HemosIL FIX Deficient Plasma
HemosIL FV Deficient Plasma
HemosIL FVII Deficient Plasma
HemosIL FVIII Deficient Plasma
HemosIL FVIII Deficient Plasma with normal vWF
HemosIL FX Deficient Plasma
HemosIL FXI Deficient Plasma
HemosIL FXII Deficient Plasma
Calibrators and Controls
For testing on ACL TOP and ACL AcuStar Systems
Normal and abnormal controls are available for all HemosIL assays, including both assayed and unassayed formats, and special tests. Assayed Control plasmas have excellent 24-hour stability. Controls for ACL AcuStars assays also available.
Calibration Plasma
High Abnormal Control
INR Validate
ISI Calibrate
Low Abnormal Control
Low Fibrinogen Control
Normal Control
Special Test Control Level 1
Special Test Control Level 2
Solutions
AcuStar Cleaning Solution**
AcuStar System Rinse**
AcuStar Triggers**
Cleaning Agent (Clean B)
Cleaning Solution (Clean A)
Factor Diluent
Rinse Solution (for ACL TOP Family)
** Chemiluminescent technology assay. For Use on ACL AcuStar Hemostasis Testing System.
Bioreagents
Antithrombin (10 UI)
Antithrombin (25 UI)
Factor Xa (71 nkat)
Chromogenic Substrates
S - 2238
S – 2222
S – 2251
S – 2288
S – 2302
S – 2366
S – 2403
S – 2765